USA Flag - Thin Blue LineUSA Flag - Full Color
Made in the USA

Enhanced DiversionDevice (EDD)

M84‑class output with electronic safe‑arm control,

low‑roll geometry, and selectable effect.

Solves Known NFDD/SFDD Failure Modes

Electronic initiation, controlled delay, low‑roll geometry, upward‑vented plume, and inert‑until‑thrown reloads—engineered to reduce roll‑aways, ignition/frag risk, and timing drift.

EDD variable load decibels
Enhanced Diversion Device

NFDD‑Class Effect. Less Fallout.

172 or 182 dB at 5 ft • 8–9 million candela Low‑roll body • 1.5‑second digital delay (±0 setpoint)

Multi-Mission

Select 172 or 182 dB to match room volume and mission profile.

Clean Reaction

Upward‑vented fuel‑air event reduces ignition risk and secondary fragmentation.

Cool-Touch Casing

Housing remains touch‑safe immediately after function.

Compliance Clarity

Componentized architecture—initiator and reload are unregulated when separated.

EDD Initiator

Electronic Safe & Arm (ESAD).

Reusable initiator with LED status • 1.5‑second digital delay • 60‑second auto‑neutralize
EDD LED indicators

LED Status

Multi‑color LEDs indicate SAFE/ARM/FIRE states and render‑safe.

Electronic Activation

Digital safe‑arm control; no pyrotechnic fuze to drift or vary.

Auto-Neutralization

60‑second fail‑safe with visual alert prevents unattended hazard.

Precise Delay

1.5s standard delay (±0 setpoint); consistent timing at operator scale.

EDD Durability
EDD Reload

Scalable Output.

Selectable 172 or 182 dB at 5 ft • 8–9 million candela • Inert until thrown • Upward‑vented plume

Inert Until Thrown

Binary energetics minimize pre‑initiation hazard.

Choose the Output

172 or 182 dB to scale effect to environment and tactics.

Cool‑Touch Housing

Post‑event pickup without hot fragments; thermal design reduces burn risk.

Replaceable Reloads

Swap spent reloads with standard tools to cut downtime and total cost.

EDD Trainer

EDD Trainer.

Same controls and timing as live • 140 dB training reload • No Flash
EDD Trainer

Same Controls

Mirrors operational handling and 1.5s digital delay for reps that transfer.

Reusable Body

Built for repeated training cycles and range throughput.

Trainer Device Reload

140 dB per training reload reduces hearing burden versus full‑effect loads.

Low‑Cost Trainer Loads

Quick reload swaps accelerate line flow and lower per‑rep cost.

Loading gallery...

Technical Specifications

Request Information

Get detailed technical specifications, pricing, and deployment guidance.

CLICK to CALL720-779-8653

Shipping Address